Silicon-based Photon Counting Computed Tomography for Advanced Cardiac Imaging

Sponsor
Ronny R Buechel, MD
Study ID
NCT07411196
Status
Not Yet Recruiting

Notify me when recruiting opens

Save your spot on the interest list for this study. We'll keep your details with this study so our team can follow up when recruiting opens.

Not yet recruiting

Add your contact details and location so we can keep your interest tied to this study.

Conditions

  • Coronary Artery Disease

Eligibility Criteria

Sex
ALL
Age
18 Years - N/A
Healthy Volunteers
Not accepted

Interventions

  • Photon-counting computed tomography — DEVICE
    Device is a novel second generation photon-counting CT device with silicon-based detectors

Study Details

Computed tomography (CT) is a key imaging modality, with rapidly increasing use in cardiovascular diagnostics. Coronary CT angiography (CCTA) provides high-resolution, non-invasive assessment of coronary anatomy and is now recommended as a first-line test for suspected coronary artery disease (CAD) due to its excellent sensitivity, allowing for the firm exclusion of the disease. CCTA, accompanied by coronary artery calcium (CAC) scanning have become, therefore, recommended as the first-line diagnostic modalities in a majority of patients with suspected CAD. It is thanks to the steady efforts to improve this modality's diagnostic performance further and reduce patients' exposure to radiation and contrast agents that have contributed to the successful implementation of this modality in routine clinical practice. However, further progress with conventional energy-integrating detector (EID) CT is limited by detector physics, as EIDs measure only total deposited x-ray energy. By contrast, photon-counting CT (PCCT) introduces semiconductor detectors that register individual photons and their energies, enabling higher spatial resolution, improved contrast-to-noise, and intrinsic spectral imaging. Early PCCT systems have shown better visualization of small coronary structures and reduced blooming, though limitations such as degraded energy resolution at high speeds and cross-talk still restrict full spectral performance. Radiation dose reductions are possible but have not yet been consistently achieved compared with optimized EID-CCTA, which is critical if PCCT is to be used for risk stratification or screening. There remains a need to better exploit PCCT's spectral capabilities for plaque and stent evaluation while maintaining acceptable radiation and contrast exposure. By 2026, second-generation silicon-based scanners (Si-PCCT) are approaching, offering potential improvements over first-generation cadmium-telluride systems. The present study aims to evaluate the diagnostic performance of such devices and exploit their technical advantages to lower radiation dose.

Key Dates

First listed
Feb 13, 2026
Start date
Aug 1, 2026
Status verified
Feb 2026
Primary completion
Jan 31, 2029
Completion
Jan 31, 2029

Study Design

Enrollment
1,000 participants (estimated)
Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC

Arms

  • Other: Patients underdoing clinically indicated coronary CT angiography
    All participants will undergo both clinically indicated coronary CT on a conventional CT scanner plus additional coronary CT on the photon-counting CT scanner

Primary Outcome Measure

Image quality of standard and low-dose Si-PCCT CCTA acquisition protocols versus the standard-of-care EID-CT CCTA protocol. [ Time Frame: Same day as enrollment ]