The Effectiveness of High-intensity Laser Therapy After Arthroscopic Shoulder Rotator Cuff Repair.
- Sponsor
- Istituto Ortopedico Rizzoli
- Study ID
- NCT07568288
- Status
- Not Yet Recruiting
Notify me when recruiting opens
Save your spot on the interest list for this study. We'll keep your details with this study so our team can follow up when recruiting opens.
Add your contact details and location so we can keep your interest tied to this study.
Conditions
- Rotator Cuff Tears
Eligibility Criteria
- Sex
- ALL
- Age
- 30 Years - 70 Years
- Healthy Volunteers
- Not accepted
Interventions
- High intensity laser therapy — DEVICEHigh-intensity laser therapy (HILT) will be administered using the HIRO TT device (ASA s.r.l., Italy), based on a solid-state Nd:YAG laser source with near-infrared emission at a wavelength of 1064 nm. The treatment protocol consists of 10 sessions delivered on alternate days. Each session will last 60 minutes and will include 15 minutes of laser therapy followed by 45 minutes of conventional physiotherapy. Laser therapy will be applied to two areas of 10 × 10 cm each, located at the anterolateral and posterior aspects of the shoulder. The treatment will be delivered using a pulsed emission with a frequency of 15 Hz, a total energy of 1000 J, and an energy density of 5 J/cm². The mean power will range between 6 and 10.5 W, with a peak power between 1 and 3 kW, for a total application time of 8 minutes and 30 seconds.
- Sham laser therapy — OTHERThe sham laser intervention will be delivered using the same HIRO TT device and identical treatment procedures as the active HILT group. The same anatomical areas (two treatment areas of 10 × 10 cm located at the anterolateral and posterior aspects of the shoulder) will be targeted, with identical session duration and patient positioning. During sham treatment, the device will remain switched on; however, no therapeutic laser emission will be delivered. This approach is intended to ensure participant blinding by replicating the visual and procedural aspects of the active intervention without providing any active therapeutic effect.
Study Details
This randomized controlled trial aims to evaluate the effectiveness of high-intensity laser therapy (HILT) as an adjunct to conventional rehabilitation in patients undergoing arthroscopic rotator cuff repair. Despite surgical repair, patients frequently experience postoperative pain, limited range of motion, and delayed functional recovery. Conventional physiotherapy represents the standard of care; however, additional strategies may be needed to optimize outcomes. High-intensity laser therapy has been proposed as a non-invasive intervention with potential analgesic and anti-inflammatory effects, but its effectiveness in the postoperative setting remains unclear. Participants will be randomly allocated to one of two groups: an experimental group receiving HILT in addition to conventional physiotherapy, and a control group receiving sham laser therapy combined with the same rehabilitation program. Both groups will undergo standardized rehabilitation sessions including therapeutic exercise. The primary outcome is pain intensity, measured using the Visual Analog Scale. Secondary outcomes include shoulder range of motion (active and passive), muscle strength, functional status assessed with the Constant-Murley Score, and patient-reported disability and quality of life measured using the Shoulder Pain and Disability Index and the Quick Disabilities of the Arm, Shoulder and Hand. Assessments will be conducted at baseline (at the start of rehabilitation), during the intervention period after the fourth (T1), seventh (T2), and tenth (T3) physiotherapy sessions, and at follow-up at 4 months.
Key Dates
- First listed
- May 5, 2026
- Start date
- Sep 30, 2026
- Status verified
- Apr 2026
- Primary completion
- Nov 30, 2028
- Completion
- Sep 30, 2029
Study Design
- Enrollment
- 46 participants (estimated)
- Allocation
- RANDOMIZED
- Intervention model
- PARALLEL
- Primary purpose
- TREATMENT
Arms
- Experimental: High level laser therapy groupHigh-intensity laser therapy (HILT) will be administered using the HIRO TT device (ASA s.r.l., Italy), based on a solid-state Nd:YAG laser source with near-infrared emission at a wavelength of 1064 nm. The treatment protocol consists of 10 sessions delivered on alternate days. Each session will last 60 minutes and will include 15 minutes of laser therapy followed by 45 minutes of conventional physiotherapy. Laser therapy will be applied to two areas of 10 × 10 cm each, located at the anterolateral and posterior aspects of the shoulder. The treatment will be delivered using a pulsed emission with a frequency of 15 Hz, a total energy of 1000 J, and an energy density of 5 J/cm². The mean power will range between 6 and 10.5 W, with a peak power between 1 and 3 kW, for a total application time of 8 minutes and 30 seconds.
- Sham Comparator: Sham laser therapy groupThe sham laser intervention will be delivered using the same HIRO TT device and identical treatment procedures as the active HILT group. The same anatomical areas (two treatment areas of 10 × 10 cm located at the anterolateral and posterior aspects of the shoulder) will be targeted, with identical session duration and patient positioning. During sham treatment, the device will remain switched on; however, no therapeutic laser emission will be delivered. This approach is intended to ensure participant blinding by replicating the visual and procedural aspects of the active intervention without providing any active therapeutic effect.
Primary Outcome Measure
Visual Analogue Scale [ Time Frame: after 3 weeks ]
Central Contacts
- Lisa Berti, MD0516366197
Related Studies
- E-CEL UVEC Cells as an Adjunct Cell Therapy for the Arthroscopic Rotator Cuff Repair in AdultsPHASE1 · Enrolling By Invitation · Hospital for Special Surgery, New York · New York, New York
- Evaluating Hemidiaphragmatic Paralysis With Prolonged Neural Blockade From an Interscalene Brachial Plexus BlockRecruiting · Duke University · Durham, North Carolina
- Genetic Epidemiology of Rotator Cuff Tears: The cuffGEN StudyRecruiting · University of Michigan · Iowa City, Iowa
- Sex Hormone Supplementation and Rotator Cuff Repair: A Preliminary Randomized TrialPHASE2 · Recruiting · University of Utah · Salt Lake City, Utah