Comparison of Two Rotational Alignment Methods for Astigmatism Correction in SMILE Surgery

Sponsor
Zhongshan Ophthalmic Center, Sun Yat-sen University
Study ID
NCT07696468
Status
Not Yet Recruiting

Notify me when recruiting opens

Save your spot on the interest list for this study. We'll keep your details with this study so our team can follow up when recruiting opens.

Not yet recruiting

Add your contact details and location so we can keep your interest tied to this study.

Conditions

  • Myopia
  • Refractive Ametropia

Eligibility Criteria

Sex
ALL
Age
18 Years - 40 Years
Healthy Volunteers
Not accepted

Interventions

  • Device-assisted cyclotorsion control during SMILE — PROCEDURE
    One eye of each participant will undergo SMILE using device-assisted cyclotorsion control with the OcuLign function of the VISUMAX 800 platform. During surgery, OcuLign will assist in identifying ocular rotation and guiding astigmatic axis alignment. Apart from the cyclotorsion adjustment method, the surgical parameters, lenticule design, suction procedure, postoperative medication, and follow-up schedule will be the same as those used for the fellow eye.
  • Manual limbal marking-guided cyclotorsion adjustment during SMILE — PROCEDURE
    The fellow eye of each participant will undergo SMILE using manual limbal marking-guided cyclotorsion adjustment. Limbal reference marks will be made in the upright preoperative position, and intraoperative axis alignment will be manually adjusted according to the limbal marks and the surgical reference direction. Apart from the cyclotorsion adjustment method, the surgical parameters, surgical procedure, postoperative medication, and follow-up schedule will be the same as those used for the contralateral eye.

Study Details

Small incision lenticule extraction (SMILE) is a commonly used corneal refractive procedure for correcting myopia and myopic astigmatism. During astigmatism correction, eye rotation between the upright examination position and the supine surgical position may affect the alignment of the astigmatic treatment axis and may contribute to residual astigmatism after surgery. Manual limbal marking is a commonly used method to guide cyclotorsion adjustment during refractive surgery. OcuLign is an assisted cyclotorsion control function of the VISUMAX 800 platform that helps identify ocular rotation and guide axis alignment during SMILE. However, direct clinical evidence comparing OcuLign-assisted cyclotorsion control with manual limbal marking during SMILE is limited. This study is a single-center, prospective, randomized, masked, contralateral-eye non-inferiority trial. Adults aged 18 to 40 years with stable myopia and astigmatism who plan to undergo bilateral SMILE surgery will be enrolled. In each participant, one eye will receive SMILE with OcuLign-assisted cyclotorsion control, and the fellow eye will receive SMILE with manual limbal marking-guided cyclotorsion adjustment. The treatment assigned to the right eye will be determined by randomization. The primary objective is to compare residual refractive astigmatism at 3 months after surgery between the two methods. Secondary outcomes include visual acuity, refractive predictability and stability, astigmatism vector analysis, higher-order aberrations, contrast sensitivity, patient-reported quality of vision, overall satisfaction, and safety outcomes. Participants will be followed for approximately 6 months after surgery.

Key Dates

First listed
Jul 10, 2026
Start date
Jul 13, 2026
Status verified
Jul 2026
Primary completion
Jun 30, 2027
Completion
Jun 30, 2027

Study Design

Enrollment
52 participants (estimated)
Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT

Arms

  • Experimental: OcuLign-Assisted Cyclotorsion Control
    One eye of each participant will undergo SMILE using OcuLign-assisted cyclotorsion control on the VISUMAX 800 platform. OcuLign will be used intraoperatively to assist in identifying ocular rotation and guiding astigmatic axis alignment. Apart from the cyclotorsion adjustment method, the surgical parameters, lenticule design, suction procedure, postoperative medication, and follow-up schedule will be the same as those used for the fellow eye.
  • Active Comparator: Manual Limbal Marking-Guided Adjustment
    The fellow eye of each participant will undergo SMILE using manual limbal marking-guided cyclotorsion adjustment. Limbal reference marks will be made in the upright preoperative position, and intraoperative axis alignment will be manually adjusted according to the marks and the surgical reference direction. Apart from the cyclotorsion adjustment method, the surgical parameters, surgical procedure, postoperative medication, and follow-up schedule will be the same as those used for the contralateral eye.

Primary Outcome Measure

Residual refractive astigmatism [ Time Frame: 3 months after surgery ]

Related Studies