A Comparison of Cyclic Manual Direct Aspiration Thrombectomy (Plunger Technique) vs. Static Manual Direct Aspiration Thrombectomy for Treatment of Acute Large Vessel Occlusion Stroke

Part of paid clinical trials in Nashville, Tennessee.

Sponsor
Vanderbilt University Medical Center
Study ID
NCT07231380
Status
Recruiting

Conditions

  • Acute Ischemic Stroke Patients
  • Large Vessel Occlusion

Eligibility Criteria

Sex
ALL
Age
18 Years - N/A
Healthy Volunteers
Not accepted

Interventions

  • Plunger Technique — PROCEDURE
    Rhythmic, cyclic application of suction using FDA-approved devices (Raptor Aspiration Catheter and VacLok Syringe) for clot removal in acute ischemic stroke.
  • Static Manual Aspiration Thrombectomy — PROCEDURE
    Continuous suction without modulation using FDA-approved devices (Raptor Aspiration Catheter and VacLok Syringe) for clot removal in acute ischemic stroke.

Study Details

This prospective, randomized controlled trial will compare two manual aspiration techniques for treating acute ischemic stroke due to large vessel occlusion: cyclic aspiration (Plunger technique) and static aspiration. Both techniques use FDA-approved devices (Raptor Aspiration Catheters and VacLok syringes) and are standard of care. Approximately 500 participants across 20 sites will be randomized to one of the two techniques. The primary endpoint is First Pass Effect (TICI 2c/3 after first attempt), with secondary endpoints including overall recanalization and 90-day functional outcomes. Results will address a critical gap in optimizing aspiration thrombectomy techniques.

Key Dates

First listed
Nov 17, 2025
Start date
Aug 10, 2026
Status verified
Aug 2026
Primary completion
Jun 1, 2027
Completion
Jun 1, 2027

Study Design

Enrollment
500 participants (estimated)
Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT

Arms

  • Active Comparator: Plunger Technique arm
    Participants randomized to this arm will undergo cyclic manual aspiration thrombectomy, also known as the Plunger Technique. This technique involves rhythmic, cyclic application of suction using FDA-approved devices: the Raptor Aspiration Catheter and VacLok Syringe, to remove thrombus in cases of acute ischemic stroke due to large vessel occlusion (terminal ICA or M1 segment of MCA).
  • Active Comparator: Manual Static Aspiration Arm
    Participants randomized to this arm will undergo static manual aspiration thrombectomy, which involves continuous suction without modulation. The procedure will use FDA-approved devices: the Raptor Aspiration Catheter and VacLok Syringe, to remove thrombus in cases of acute ischemic stroke due to large vessel occlusion (terminal ICA or M1 segment of MCA).

Primary Outcome Measure

First Pass Effect (FPE) [ Time Frame: During Procedure ]

Central Contacts

Locations (1)

FacilityCityStateZIPSite coordinators
Vanderbilt University Medical CenterNashvilleTennessee37232
Anna Bican
Rohan Chitale (SUB_INVESTIGATOR)
Kunal Raygor (SUB_INVESTIGATOR)
Matthew Fusco (SUB_INVESTIGATOR)
Michael Froehler (PRINCIPAL_INVESTIGATOR)

Find similar trials in Nashville, TN

Related Studies