Optimizing Noisy Galvanic Vestibular Stimulation Frequency Range for Enhancing Vestibular Perception and Manual Control Performance

Part of paid clinical trials in Houston, Texas.

Sponsor
National Aeronautics and Space Administration (NASA)
Study ID
NCT07730398
Status
Completed

Conditions

  • Sensorimotor Performance
  • Vestibular Function Tests

Eligibility Criteria

Sex
ALL
Age
22 Years - N/A
Healthy Volunteers
Accepted

Interventions

  • Low-frequency noisy galvanic vestibular stimulation (nGVS) — DEVICE
    Participants received low-frequency noisy galvanic vestibular stimulation through electrodes placed over the bilateral mastoid processes during experimental testing. Stimulation parameters were consistent with the approved study protocol. Frequency was 0-2Hz white noise, 300uA amplitude.
  • High-frequency noisy galvanic vestibular stimulation (nGVS) — DEVICE
    Participants received high-frequency noisy galvanic vestibular stimulation through electrodes placed over the bilateral mastoid processes during experimental testing. Stimulation parameters were consistent with the approved study protocol. Frequency was 10-30Hz white noise, 300uA amplitude.

Study Details

This randomized crossover interventional study evaluated the effects of different frequency ranges of noisy galvanic vestibular stimulation (nGVS) on vestibular perception, perceptual motion tracking, and manual control performance in healthy adults. Each participant completed three experimental conditions in randomized order: no stimulation (control), low-frequency nGVS, and high-frequency nGVS. Vestibular perceptual thresholds, perceptual tracking, and manual control performance were assessed during each condition to determine whether stimulation frequency influenced sensorimotor function.

Key Dates

First listed
Jul 28, 2026
Start date
Feb 19, 2024
Status verified
Jul 2026
Primary completion
Mar 18, 2024
Completion
Mar 18, 2024

Study Design

Enrollment
18 participants (actual)
Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
BASIC_SCIENCE

Arms

  • No Intervention: Control - No noisy galvanic vestibular stimulation
    Participants completed testing without noisy galvanic vestibular stimulation.
  • Experimental: Low-frequency noisy galvanic vestibular stimulation
    Participants received low-frequency noisy galvanic vestibular stimulation during testing. Low frequency was 0-2 Hz.
  • Experimental: High-frequency noisy galvanic vestibular stimulation
    Participants received high-frequency noisy galvanic vestibular stimulation during testing. High-frequency was 10-30 Hz.

Primary Outcome Measure

Vestibular Direction Recognition Threshold [ Time Frame: Day 1 (single study visit): Participants completed outcome assessments during each randomized intervention condition (No nGVS, Low-Frequency nGVS, and High-Frequency nGVS). Each assessment required approximately 5 minutes to complete. ]

Locations (1)

FacilityCityStateZIPSite coordinators
Nasa Jsc B21HoustonTexas77058-

Find similar trials in Houston, TX