STRATegy SUccesS in High-Risk PCI With Impella CP: Evaluation of Hemodynamic Protection in Complex PCI

Sponsor
Rayyan Hemetsberger
Study ID
NCT07588399
Status
Not Yet Recruiting

Notify me when recruiting opens

Save your spot on the interest list for this study. We'll keep your details with this study so our team can follow up when recruiting opens.

Not yet recruiting

Add your contact details and location so we can keep your interest tied to this study.

Conditions

Eligibility Criteria

Sex
ALL
Age
18 Years - N/A
Healthy Volunteers
Not accepted

Interventions

  • Impella CP — DEVICE
    The Impella CP is a transvalvular axial-flow micro-pump for temporary mechanical circulatory support, inserted via a 14F sheath into the femoral artery and positioned across the aortic valve. The pump draws blood from the left ventricle and delivers it to the ascending aorta, providing forward flow up to approximately 4.3 L/min while reducing left ventricular work and end-diastolic pressure. In this study, the device is used in all participants undergoing protected high-risk PCI, with the operating modality (Auto-mode in the experimental arm vs. fixed P-2 mode in the active comparator arm) determined by 1:1 randomization. The unblinded study investigator may escalate Impella support if predefined hemodynamic instability criteria are met.

Study Details

STRATUS-PCI is a pilot clinical trial that compares two ways of running a small heart pump called Impella CP during a high-risk procedure to open blocked heart arteries (percutaneous coronary intervention, or PCI) in patients with weakened heart muscle. The pump is placed temporarily through an artery in the leg and sits across the aortic valve to help maintain blood flow during the procedure. Fifty patients will be randomly assigned in equal numbers to one of two pump settings: an automatic mode that adjusts flow up to higher levels as needed, or a fixed lower-flow mode (P-2). The doctor performing the heart procedure will not know which setting is being used (double-blind). A separate doctor monitors blood pressure and is allowed to change the pump setting at any time if the patient becomes unstable. The main question is whether the automatic mode helps doctors complete the planned heart procedure more successfully and without drops in blood pressure or other complications. Results will help design a larger future trial.

Key Dates

First listed
May 14, 2026
Start date
Jul 1, 2026
Status verified
May 2026
Primary completion
Jul 1, 2027
Completion
Oct 1, 2027

Study Design

Enrollment
50 participants (estimated)
Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT

Arms

  • Experimental: Impella CP Auto-mode
    Patients in this arm receive temporary mechanical circulatory support with the Impella CP transvalvular axial-flow pump operating in Auto-mode (SmartAssist) throughout the protected high-risk percutaneous coronary intervention. In Auto-mode, pump speed (P-level) is automatically adjusted in real time based on hemodynamic feedback, with maximum flow up to approximately 4.3 L/min.
  • Active Comparator: Impella CP P-2 Mode
    Patients in this arm receive temporary mechanical circulatory support with the Impella CP transvalvular axial-flow pump operating in the fixed P-2 setting (approximately 1.3-2.1 L/min flow) at the start of the procedure. The unblinded study investigator continuously monitors hemodynamics during the procedure and is empowered to escalate Impella support to a higher P-level (or Auto-mode) without operator confirmation if any predefined hemodynamic instability criterion is met (MAP drop ≥ 25 mmHg, MAP \< 60 mmHg for \> 1 minute, flat line, catecholamine need, periprocedural resuscitation, or ventilation).

Primary Outcome Measure

Strategy Success [ Time Frame: 48 hours ]

Central Contacts

Find similar trials

Related Studies