Prospective Study on the Effectiveness and Safety of Bi-polar Pulse-field Tip-catheter Ablation for Atrial Fibrillation in China(POTENTIAL-AF)

Sponsor
Beijing Anzhen Hospital
Study ID
NCT07627685
Status
Not Yet Recruiting

Notify me when recruiting opens

Save your spot on the interest list for this study. We'll keep your details with this study so our team can follow up when recruiting opens.

Not yet recruiting

Add your contact details and location so we can keep your interest tied to this study.

Conditions

Eligibility Criteria

Sex
ALL
Age
18 Years - N/A
Healthy Volunteers
Accepted

Interventions

  • Bi-polar Pulse-field Ablation (PFA) - LEAD-PFA System with PulsedFA catheter — DEVICE
    Participants undergo catheter ablation for atrial fibrillation using the Jinjiang bi-polar pulse-field ablation (PFA) system, comprising the LEAD-PFA generator and PulsedFA circular catheter (Jinjiang Electronic Medical Technology Co., Ltd., Sichuan, China). Catheter size (15 mm, 18 mm, or 25 mm) is selected by the operator based on individual anatomy. All patients undergo pulmonary vein isolation (PVI) as the mandatory ablation target. A minimum of 12 PFA applications are delivered per pulmonary vein (≥ 48 applications in total). Energy is delivered in bipolar mode at 2.0 kV, with each application comprising 5 pulse sequences over 2.5 seconds, non-synchronised to the QRS complex. Electrophysiological verification of entrance block (and exit block where applicable) is performed after PVI; additional applications are permitted if acute conduction recovery is observed.

Study Details

POTENTIAL-AF is a prospective, multicentre, observational registry study evaluating the real-world effectiveness and safety of bi-polar pulse-field tip-catheter ablation (PFA) for atrial fibrillation (AF) in China. The study will enrol 30,000 adult patients with symptomatic paroxysmal or persistent AF who have failed at least one antiarrhythmic drug (Class I or III) and are planned to undergo PFA using the Jinjiang LEAD-PFA system with PulsedFA catheter at participating centres across China. All procedural decisions, including energy settings, ablation targets, and peri-procedural management, are made by the treating physician per routine clinical practice. The study prospectively collects baseline clinical characteristics, intraoperative ablation parameters, and follow-up outcomes at 3 months, 6 months, 12 months, and every 6 months thereafter, for up to 10 years. The primary endpoint is all-cause mortality at 10 years. Secondary endpoints (observed over 5 years) include ischaemic stroke, haemorrhagic stroke, transient ischaemic attack (TIA), cardiovascular death, cardiovascular hospitalisation, systemic embolism, thromboembolic death, major bleeding, and clinically relevant non-major bleeding (CRNMB). By capturing large-scale, standardised, long-term data across diverse Chinese centres, POTENTIAL-AF aims to describe real-world procedural practice patterns, identify predictors of clinical outcomes, and provide evidence to support the safe and effective application of the Jinjiang bi-polar tip PFA catheter in Chinese AF patients.

Key Dates

First listed
Jun 4, 2026
Start date
Sep 1, 2026
Status verified
May 2026
Primary completion
Sep 1, 2036
Completion
Sep 30, 2036

Study Design

Enrollment
30,000 participants (estimated)

Arms

  • Arm: PFA Ablation Cohort
    All enrolled patients undergoing bi-polar pulse-field ablation for atrial fibrillation using the Jinjiang LEAD-PFA system with PulsedFA catheter at participating centres. Peri-procedural management and post-procedural medical therapy are at the treating physician's clinical discretion; no additional protocol-mandated treatment is assigned.

Primary Outcome Measure

All-Cause Mortality [ Time Frame: From enrolment to 10 years ]

Central Contacts