Efficacy of the Use of Real-time Continuous Glucose Monitoring on Glycemic Control in Patients With Type 2 Diabetes and Stage 3 and 4 Chronic Kidney Disease.

Sponsor
Hospital Universitario San Ignacio
Study ID
NCT07668219
Status
Not Yet Recruiting

Notify me when recruiting opens

Save your spot on the interest list for this study. We'll keep your details with this study so our team can follow up when recruiting opens.

Not yet recruiting

Add your contact details and location so we can keep your interest tied to this study.

Conditions

Eligibility Criteria

Sex
ALL
Age
18 Years - N/A
Healthy Volunteers
Not accepted

Interventions

  • Real time continuos glucose monitoring — DEVICE
    Intervention group (users of real-time continuous glucose monitoring). Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring. This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device. Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL. Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (\<54 mg/dL and \<70 mg/dL) or recurrent hyperglycemic episodes (\>180 mg/dL), according to basal and prandial insulin titration recommendations. This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's accuracy withi
  • self blood glucose monitoring — DEVICE
    Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study. Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes. Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (\<54 mg/dL and \<70 mg/dL) or recurrent hyperglycemic events (\>180 mg/dL), according to basal and prandial insulin titration recommendations.

Study Details

* Rationale: Glucose control in patients with kidney disease is challenging, as traditional metrics can be unreliable and there is a high risk of hypoglycemia (low blood sugar). Although RT-CGM has shown benefits in other groups, its efficacy in patients with advanced kidney damage needs to be validated to improve their quality of life and prevent disease progression. * Main objective: To determine whether the use of RT-CGM is more effective than usual care (capillary blood glucose monitoring with a glucometer) in maintaining patients within an optimal glucose range (70-180 mg/dL) over a three-month period. * Study population: We plan to include 30 patients over 18 years of age with type 2 diabetes and chronic kidney disease (with a glomerular filtration rate less than 60 ml/min), who use insulin and are not on renal replacement therapy such as dialysis. * Methodology: The study is a randomized clinical trial consisting of two phases: 1. Selection period (15 days): Blinded monitoring is performed to obtain baseline data. 2. Treatment period (90 days): Patients are divided into two groups: the intervention group, which will use the CGM-RT with alarms configured for high and low levels, and the control group, which will continue with traditional fingerstick monitoring. * Metrics to be evaluated: In addition to time in range, researchers will analyze episodes of hypoglycemia and hyperglycemia, glycemic variability, glycated hemoglobin (HbA1c) levels, and device accuracy. * Ethical and logistical considerations: The study complies with international and national regulations, guaranteeing the confidentiality and autonomy of the participants. The project has a 24-month timeline and a detailed budget to cover medical personnel, monitoring sensors (Sinocare i3), and laboratory tests.

Key Dates

First listed
Jun 25, 2026
Start date
Nov 30, 2026
Status verified
Jun 2026
Primary completion
Feb 1, 2027
Completion
May 30, 2027

Study Design

Enrollment
30 participants (estimated)
Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT

Arms

  • Active Comparator: Self-monitoring blood glucose
    Control group: Continuous glucose monitoring will be installed, blinded to measure baseline glycemic control metrics and at the end of the study. Patients assigned to the control group will receive routine nursing education on glucometer use, frequency of capillary blood glucose monitoring, and recommendations for managing hypoglycemic episodes. Capillary glucose data will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if subjects experience hypoglycemic events (\<54 mg/dL and \<70 mg/dL) or recurrent hyperglycemic events (\>180 mg/dL), according to basal and prandial insulin titration recommendations.
  • Experimental: RT-CGM
    Description: Intervention group (users of real-time continuous glucose monitoring). Participants in the intervention group will be instructed on the use of real-time continuous glucose monitoring. This training will be provided by nursing staff and will include instruction on device use, alarm management, and recommendations for responding to hypoglycemic episodes reported by the device. Alarms will be configured as follows: High Glucose Alert ≥240 mg/dL and Low Glucose Alert ≤70 mg/dL. Data uploaded to the platform by the device will be reviewed monthly by a physician trained in diabetes management, who will make appropriate adjustments to therapy if participants experience hypoglycemic episodes (\<54 mg/dL and \<70 mg/dL) or recurrent hyperglycemic episodes (\>180 mg/dL), according to basal and prandial insulin titration recommendations. This group will be instructed to confirm readings below 70 mg/dL and above 240 mg/dL with capillary blood glucose monitoring to evaluate the device's

Primary Outcome Measure

Time in range (TIR) [ Time Frame: 12 weeks ]